| BMA1265, BMA2285, BMA22105 | BMA125, BMA165, BMA205 |
Semi-Micro Analytical Balance BMA Series
1. Electromagnetic force recovery weighing system
2. Highly integrated load cell
3. Recipe database: can store 99 recipes, each recipe contains up to 20 ingredients
4. Large graphic display, easy and efficient operation
5. Multiple languages are supported: English, German, French, Italian, Spanish, Portuguese
6. Record the saved weight value in GLP/ISO format, including date, time, and serial number
7. Large windshield glass cover, with 3 sliding doors, easy to operate the items to be weighed
8. Keyboard plastic protection
| Model | BMA1265 | BMA2285 | BMA22105 | BMA125 | BMA165 | BMA205 |
| Capacity(g) | 62g/120g | 82g/220g | 102g/220g | 122g | 162g | 210g |
| Resolution(mg) | 0.01mg/0.1mg | 0.01mg | ||||
| Min Weighing(mg) | 60mg | 100mg | ||||
| Stable Time | ≤6s | |||||
| Display | LCD(white back light with black font) | |||||
| Pan Size | Φ80mm | |||||
| Operation Temp | 5-35℃ 20-80% humidity | |||||
| Repeatability | 0.03mg/0.1mg | 0.05mg/0.1mg | 0.05mg | 0.05mg | ||
| Liner | ±0.08/±0.2mg | ±0.1/ ±0.2mg | ±0.1mg | ±0.1mg | ||
| Draft Shield Size | 152mm×160mm×225mm | |||||
| Cal.weight | Internal Calibration | |||||
| Option | Printer | |||||
| Package | 620*510*710mm | |||||
| G.W./N.W. | 8.25kg/5.8kg | 8.3kg/5.85kg | ||||
| IONISER | Option | Standard | ||||
| Language | Italian/English/Portuguese/German/France/Spanish | |||||
| Packing Size | 510x400x620mm(No pallet) | |||||
| Power Supply | 110-230V 50/60Hz Out DC 12V 1A | |||||
Analytical balances are highly sensitive lab instruments designed to accurately measure mass.
Analytical balances are highly sensitive lab instruments. The Analytical balances are a special type of balance that offers very accurate measurements, designed to measure small mass in the sub-milligram range. usually used for precision measuring instruments used in quantitative chemical analysis, BA-E series readability up to 0.0001g.
Features for Analytical balances
| Model | BA-E1004 | BA-E1104 | BA-E1204 | BA-E2004 | BA-E2104 | BA-E2204 |
| Capacity(g) | 100g | 110g | 120g | 200g | 210g | 220g |
| Resolution(g) | 0.0001g | |||||
| Min Weighing(g) | 0.0004g | |||||
| Stable Time | ≤3s | |||||
| Display | LCD(white back light with black font) | |||||
| Pan Size | Φ80mm(Standard), Φ90mm(Optional) | |||||
| Operation Temp | 5-35℃ | |||||
| Repeatability | ±0.0002g | |||||
| Liner | ±0.0003g | |||||
| Dimension | 300X200X295mm | |||||
| Draft Shield Size | 180x175x200mm | |||||
| LCD Size | 96x24mm | |||||
| Cal. weight | External Calibration | |||||
| Option | RS232C(Standard)
Printer(Optional) | |||||
| Packing Size | 440*430*430mm | |||||
| Gross Weight | 8.0kg | |||||
The analytical balance scale is a scale for daily laboratory use.
Analytical Balance Scale are precise balances with readability to .01g (5 decimal places) making them ideal for universities, pharmaceutical, and high-precision manufacturing applications.
1. LCD(White back light with black front)
2. AC and DC power supply
3. Tare function/Counting/Unit conversion(g/ct/oz)…
4. Min weighing set
5. Overload alarm/Level indicator
6. Option:Dual display/Interface/Printer/Dust cover

| AC and DC power supply |
SPECIFICATIONS
| Products | 0.001g/0.01g Analytical Balance Scale, BA-WP Series | ||
| Model | BA-W113P | BA-W213P | BA-W313P |
| Max. capacity(g) | 110 | 210 | 310 |
| Sensor | Load Cell | ||
| Readability(g) | 0.001 | ||
| Min Weighing(g) | 0.004 | ||
| Stable Time | ≤ 3s | ||
| Display | LCD(white back light with black font) | ||
| Pan size | Φ90mm | ||
| Operation temp | 5-25℃ | ||
| Repeat ability | ±0.002g | ||
| Linearity | ±0.003g | ||
| Draft shield size | 177mmx173mmx205mm | ||
| Cal.weight | 100g | 200g | |
| Option | RS232C&RS485,Printer,Dual display,USB… | ||
| Packing size | Unit sets Inside:390*300*400mm Four Outside:740x550x390mm | ||
| G.weight | 4.0/16kg | ||
LCD/AC and DC power supply
Tare function/Counting/Unit conversion (g/ct/oz)
Min weighing set
Overload alarm/Level indicator
Option: Dual display/Interface/Printer/Windproof/Dust cover
SPECIFICATIONS
| Model | BP-112-2C | BP-212-2C | BP-312-2C | BP-512-2C | BP-612-2C | BP-1102-2C | BP-2102-2C | BP-3102-2C |
| Capacity | 110 | 210 | 310 | 510 | 610 | 1100 | 2100 | 3100 |
| Cal.weight | 100 | 200 | 200 | 200 | 200 | 500 | Optional | Optional |
| Readability(g) | 0.01 | |||||||
| Repeatability(g) | ±0.02 | |||||||
| Liner(g) | ±0.03 | |||||||
| Stable Time | ≤2s | |||||||
| Pan Size | Φ130mm | |||||||
| Operation Temp | 5-25℃ | |||||||
| Option | Printer, Draft shield, RS232, Weight | |||||||
| Outline Size | 270x195x85mm | |||||||
| Unit set Packing Size | 330*260*200mm | |||||||
| Ten Packing Size | 660x470x320mm | |||||||
| Net Weight | Unit set 2.5kg/Ten sets 25kg | |||||||
| Gross Weight | Unit set 3kg/Ten sets 30kg | |||||||
Density Balance ELD-300
——Direct reading data, Shorter measuring time, Density resolution 0.001 g/cm3
Application: Chemical Solution, Modern Energy, Oil Fuel, Fine Chemical Engineering, Chemical Reagent, Chemistry Researching Laboratory.
Standards: In accordance with Archimedes principle, GB/T 611 、GB/T11540、GB/T12206、GB/T5518 standards, etc.
Combine Archimedes principle with modern electronics technique of ELD-300; Digital display liquid decimeter; The data can be read directly with high measuring accuracy; The operation is easier and gets away from the influence of external factor and temperature compared with traditional Wechsler balance method and pycnometer method; It can be applied to the field of quality management, cost control, formula researching and so on. Also, the solvent, adhesive, paint,
pitch, resin, chemical oils, edible oil, food additives, drink, dairy products can be measured.
Features :
The density value can be shown by one procedure. and repeatedly continuous rapid measuring can be worked.
Digital Display; High accuracy of measuring; Simple operation; Stable and Durable.
The density value of samples with the temperature from normal to 100℃ can be measured.
Take samples conveniently. and 50CC would be okay.
There is no cumbersome debugging and operation compared with the traditional Wechsler balance method and pycnometer method.
It is very easy to clean measuring cup, and can’t get the limitation of the size of pycnometer caliber.
Coordinate with the operation of the thermostatic tank to measure the proportion with the required temperature.
Adopt the unicase dedicated wind and dust cover, which makes the combination convenient and durable.
Volatile liquid, corrosivity liquid,viscous liquid, strong acid, and strong lye liquid can be measured quickly.
The interface of RS-232C is included. the printer of DE-40 will be available to connect PC with printer.
Measuring Procedure:
Place beaker with sample on testing board. and take-off weight of pothook.
Make standard weight hanged on pothook and submerged in liquid to be tested totally. and then press the ENTER button to memory. Density value can be displayed.
Standard Accessories:
Host, measuring frame, AR-20A standard liquid measuring assembly, tweezer,
thermometer,100G weight, wind, and dust cover, measuring support, power transformer
Optional Accessories:
AR-40 printer, AR-20B anti-corrosive liquid measuring assembly.
| Name/model | ELD-300 Density Balance |
| Density resolution | 0.001g/cm3 |
| Density range | 0.001—99.999g/cm3 |
| Measuring type | a: mobility liquid,viscous liquid,volatile liquid,corrosivity liquid,high temperature liquid,suspension liquid,emulsion and so on
b: alcohol,scaling powder,essence,blood,sodium chloride,glycerol, electrolyte,diesel,refrigerating,hydrofluoric acid,dichloromethane,vitriol |
| Measuring Principle | Archimedes principle displacement method |
| Measuring mode | 1 group |
| Measuring time | About 5 seconds |
| Memory mode | memory in a shorter time by one procedure |
| Result Display | Density value |
| Specific Gravity Measuring frame | stainless steel specific gravity measuring frame |
| Function of setting | Temperature setting, solution density setting, measuring weights setting of weight in the normal liquid and water |
| Calibration mode | auto-correction with one button,auto-detection. |
| Measuring testing | distilled testing |
| Output mode | standard interface of RS-232, output and print testing data conveniently |
| Standard accessories | Host, measuring frame, AR-20A standard liquid measuring assembly, tweezer, thermometer,100G weight, measuring support, power transformer
AR-20A standard liquid measuring assembly: Two stainless steel pothooks, one glass weight, one glass beaker. |
| Optional accessories | AR-40 printer, AR-20B anti-corrosive liquid measuring assembly |
| power | AC~220V / 50HZ |
| Main feature | data display, accuracy, rapid, convenience durable, economy |

Top quality stainless steel material for

Large LCD display

The flow control valve
SPECIFICATIONS
| Model | USC0140M | USC0240M | USC0340M | USC0540M | USC0440M | USC0640M | USC1040M | USC1540M | USC2040M | USC2240M | USC3040M | USC4540M |
| Ultrasonic Power(W)-Max | 70 | 70 | 120 | 120 | 180 | 180 | 240 | 360 | 360 | 480 | 600 | 720 |
| Ultrasonic Power setting-% | 10%-100%(step by 10%) | |||||||||||
| Heating Power(W)-Max | 100 | 100 | 100 | 100 | 200 | 200 | 500 | 500 | 500 | 500 | 500 | 1000 |
| Capacity (L)-Max | 1.3 | 2 | 3.2 | 4.8 | 4.5 | 6.5 | 10 | 15 | 20 | 22 | 30 | 45 |
| Tank Size(L*W*H)-MM | 150*135*65 | 150-135*100 | 240*135*100 | 240*135*150 | 300*150*100 | 300*150*150 | 300*240*150 | 330*300*150 | 330*300*200 | 500*300*150 | 500*300*200 | 500*300*300 |
| External Size(L*W*H)-MM | 180*165*205 | 180*165*205 | 265*165*235 | 265*165*285 | 330*180*260 | 400*240*370 | 330*270*310 | 360*330*330 | 470*400*450 | 530*330*340 | 530*330*390 | 530*330*490 |
| Transducer Qty(PCS) | 1 | 1 | 2 | 2 | 3 | 3 | 4 | 6 | 6 | 8 | 10 | 12 |
| Drain Valve | No | No | Yes | |||||||||
| Carrying Handle | No | No | Yes | |||||||||
| Ultrasonic Freq(KHz) | 40 | |||||||||||
| Temperature Setting(℃)-Max | Default 60℃, optional 80℃ (free of charge, please note when ordering) | |||||||||||
| Timer Setting(MINS) | 1-99 | |||||||||||
| Cleaning Basket | Yes | |||||||||||
It has the advantages of reliable disinfection and sterilization effect, easy operation, safe use, power saving, durability, low price and excellent quality. It is an ideal equipment for disinfection and sterilization of surgical instruments, dressings, utensils, culture media, etc. in medical, health, scientific research, etc.
| Model | STV-35HD | STV-50HD | STV-75HD | STV-100HD |
| Volume | 35L
(φ318*450mm) | 50L
(φ340*550mm) | 75L
(φ400*600mm) | 100L
(φ440*650mm) |
| Design Pressure | 0.3MPa | |||
| Design Temperature | 150℃ | |||
| Max.Working Pressure | 0.25MPa | |||
| Max.Working Temperature | 138℃ | |||
| Temperature Uniformity | ≤±1℃ | |||
| Temperature Range | 105~134℃ | |||
| Timing Range | 0~99min or 0~99hour59min | |||
| Electricity | AC 220V/50Hz | |||
| Power | 1×2.5kW | 2×1.5kW | 3×1.5kW | |
| External Dimension
(W*D*H) | 470*450*1020
mm | 520*490*1150
mm | 550*530*1180
mm | 580*560*1290
mm |
| N.W. / G.W. | 65kg/84kg | 78kg/97kg | 97kg/115kg | 109kg/135kg |
| Package Dimension (W*D*H) | 540*540*1160
mm | 580*580*1280
mm | 610*610*1320
mm | 640*640*1400
mm |
It is safe, reliable and automatically controlled, suitable for medical, pharmaceutical, scientific research and other units. It can provide rapid sterilization for surgical, dental, ophthalmic instruments, glassware, medicines, culture media, fabric dressings, foods and other items that can withstand saturated steam.
| Model | STB-APV20 | STB-APV24 |
| Volume | 18L
(φ250*360mm) | 23L
(φ250*470mm) |
| Design Pressure | 0.3MPa | |
| Design Temperature | 150℃ | |
| Max.Working Pressure | 0.25MPa | |
| Max.Working Temperature | 138℃ | |
| Temperature Range | 105~134℃ | |
| Timing Range | 0~99min | |
| Temperature Uniformity | ≤±1℃ | |
| Electricity | AC 220V/50Hz, 2kW | AC 220V/50Hz, 2kW |
| External Dimension | 480*680*455mm | 480*680*455mm |
| N.W./G.W. | 47kg/60kg | 53kg/61kg |
| Package Dimension | 780*580*580mm | 780*590*570mm |





Shorter cycle time, higher efficiency
SPECIFICATIONS
| STC-2000 | |||
| Maximum Operating Pressure | 242 kPa | Input Power | ≤1.3 kVA |
| Operating Pressure Range | 42 kPa ~ 212kPa | Atmospheric Pressure Range | 70.0 kPa to 106.0 kPa |
| Maximum Operating Temperature | 138° C | Ambient Temperature Range | + 5 ° C ~ + 40 ° C |
| Operating Temperature Range | 115 ° C – 135 ° C | Steam Generator Power | 1.2 kVA ± 5% |
| Display accuracy | 0.1℃ | Fuse | F8AL250V phi 5 x 20 mm |
| Sterilization Volume | About 1.8 Liters | Safety Valve Setting Pressure | 0.25 MPa |
| Tank Volume | 3.4 Liters | Equipment Working Medium | Water Vapor |
| Water | Ultra-pure water, deionized water, laboratory water. | Working Relative Humidity | ≤85% |
| Power Supply Voltage | AC 220 V±22 V | Normal Use Place | Work room |
| Power Frequency | 50 Hz ± 1 Hz | Run Mode | Run Intermittently (≤6 cycles/hour) |
1. General requirements
1.1 The spraying of cleaning water and the dissolution and stripping of cleaning solution can assist in cleaning the inorganic residues (such as lead, mercury, cadmium, arsenic, etc.) and organic residues (such as industrial dyes, hormones, grease, dust, etc.) of laboratory glassware or plastics.
1.2 The organic residue after cleaning is less than 0.1mg/L, and the metal ion residue is less than 0.02mg/L. The provincial authoritative experimental report or certification on the cleaning effect must be provided. In order to ensure the accuracy of the experimental results of trace analysis, the equipment has passed ISO9001, CE and other relevant international authoritative certifications.
1.3 The power supply voltage is 220V.
2. Structural design
2.1 Double-layer detachable heat insulation and sound insulation shell, the inner cavity is made of 316L stainless steel, and the outer shell is made of 304 stainless steel.There are no exposed screws and rivets on the outside.
2.2 The height of the equipment is 110cm, which can be embedded in the test bench, the length and width are less than 75cm, and it occupies a small area.
2.3 There are two layers of cleaning racks in the cleaning cabin, which can clean 420 liquid phase autosampler vials or test tubes, colorimetric tubes or 72 volumetric flasks, beakers, conical flasks, etc. at a time.
2.4 Internal foaming double-layer metal door is adopted to effectively insulate and reduce energy consumption.
2.5 It has two water inlets, which can be connected to tap water and pure water at the same time, and which water needs to be entered can be selected through the operation of the control panel.
3. Control system
3.1 Microcomputer control system and color LCD screen are adopted. The tilt angle design of the operation screen conforms to the principle of ergonomics. It is easy to operate and has better user experience.
3.2 The control screen has a full Chinese operation interface, and both operations and alarms are prompted in Chinese.
3.3 The control system has 12 standard cleaning procedures and 99 custom cleaning procedures, which can be set and adjusted for different utensils and requirements.
3.4 “Black box” function, built-in data memory, the whole process of recording the cleaning status of each step, the system has self-diagnosis function, fault information prompt function;
4. Cleaning system
4.1 The cleaning water pump is a professional European original imported circulating pump. Its water output is 800L/min, the water output is large, and the scouring force is large. The circulating pump fan blades have been treated with high temperature resistance and can work normally under the disinfection water temperature (above 93 ℃).
4.2 The cleaning cabin adopts the water supply structure of parallel water supply and water inlet at the back, instead of the structure of water inlet at the top and one-way water supply at the center. Water inlet from the side, and there is no need to find the water receiving port, convenient access, and the joint is not easy to be damaged.
4.3 The cleaning rack adopts the structure of water inlet in the back and water distribution in the central part. The central part divides water, and the cleaning rack connects the water to the middle part and distributes the water evenly to each spray column to ensure that each spray column discharges water evenly and cleans the utensils uniformly.
4.4 The spray columns of the cleaning rack shall be distributed in parallel rather than around the center, so as to ensure the consistent distance between each spray column and facilitate the placement and estimation of utensils while increasing the cleaning amount.
4.5 The cleaning rack does not have a tall central water inlet pipe, which saves space and is convenient to place; the upper and lower floors of the cleaning rack can be interchanged to facilitate the arrangement of utensils.
4.6 The cleaning cabin has a built-in double-layer 360-degree rotating spray arm, and the nozzle adopts a fan-shaped nozzle design, which sprays a fan-shaped water curtain with large scouring force and no dead ends. No simple small hole nozzle is used to reduce the dead angle of external spraying.
4.7 The glassware washer adopts an automatic heating system during cleaning, and the heating temperature is adjustable. The maximum temperature can reach 93°C, reaching the disinfection level.
4.8 The cleaning solution and neutralization solution are automatically added by two peristaltic pumps, and the added dosage can be set.
5. Safety protection
5.1 Safe door lock design, the door body is locked and cannot be opened during the cleaning process, preventing water spraying and scalding caused by misoperation; It has the function of emergency door opening, which can quickly open the door and take out the utensils after power failure.
5.2 It has a complete protection function, with a lack of cleaning agent alarm, the main washing pump over-temperature protection function, heating and anti-dry function, the main washing pump idling protection function, water level sensor detection function, cleaning chamber over-temperature protection function, all have Chinese prompt and alarm reminder.
5.3 It has the function of program self-checking and equipment self-cleaning, which can perform self-checking on the set program. After cleaning, the equipment can also be automatically cleaned to reduce residues.
| Model | LWD-200I |
| The volume of the cleaning chamber | ≥200L |
| External dimensions | 607×730×1050 |
| Power supply (V/HZ) | 220V/50Hz |
| Water cleaning power | ≤0.75KW |
| water heating power | ≥3KW fast heating |
| air volume | ≥120L/M3 |
| Water temperature control | room temperature to 99℃ |
| Standard configuration | 2 cleaning racks |
| Package Dimension (W*D*H) (mm) | 1000*740*1220 |
| Equipped with 2.5L each of imported cleaning fluid and neutralizing fluid | |
Introducton:
The lab glassware washers integrate programmed cleaning, disinfecting and drying functions to clean all glassware stuff, for beaker, flask, pipette, petri dish, burette, measuring cylinder, test tube etc.
Standard Washing Procedure (can be self-designed by the user):
Pre-cleaning→Washing with cleaner→Rinse→Washing with neutralization→Rinse→Washing with hot water→Drying
Can clean all laboratory glassware (not limited to the types shown in the figure below), accept custom cleaning racks
Microprocessor Control System:
7’’ LCD display touch screen, microprocessor with PLC system which is various of programmable washer cycles, detergent volume etc. User programmable with 99 storable programs and denable. All significant parameters can be set. These include: execution times, operating temperatures, quantity of additives, number of phases, and so on. Access to the control operations is protected by a system of four user passwords.
Reliability:
1.Microprocessor with PLC control system anti-EMI (electrical magnetic interface )
2.7’’ colorful touch screen is easy control and observation, It display the work situation.
3.Password protection with three levels can meet different management needs which block the authorized entry.
4.Parameters setting memory for Power failure, washer cycles is going on as soon as power comes back.
5.Safety protection water temperature and dry air temperature, when the temperature exceed the setting, it will stop working.
6.Safety lock with electromagnetic release to prevent door opening while it is in wash/dry cycle.
7.Safety electrical system for circuit overload, short circuit, over current and leakage current safety emergency button for stop the unit in time.
8.Alarm system: drainage malfunction alarm, detergent/neutralizer shortage alarm, high water.
9.heating alarm etc.
10. Printer
| MODEL | LWD-420M | |
| Capacity(L) | 420 | |
| Voltage(V/Hz) | 380V/50~60HZ | 220V~240V50~60HZ |
| Washer Load Level | 2 | |
| Water Wash Power(Kw) | 2.8 | |
| Water Heater Power( Kw) | 15 | 5 |
| Dry Power(Kw) | 3.6 | |
| MAX. Power(Kw) | 17 | 7 |
| Water Consumption/Cycle(L) | 25 | |
| Tank internal temperature (℃) | 0~99 | |
| Noise(dBa) | <60 | |
| Water Supply Pressure (Mpa) | 0.3-1.0 | |
| Chamber Dimension(W*D*H mm) | 688*700*703 | |
| Exterior Dimension(W*D*H mm) | 1100*900*2165 | |
| Package dimension (W*D*H mm) | 1300*1040*2350 | |
| Net/Gross Weight (KG) | 380/420 | |
It is widely used in agriculture, medicine, food hygiene, biopharmaceuticals, bioengineering, cell biology and biochemistry, etc. It is suitable for the separation and purification of microbial cells, cell proteins, mold and immunity.
Advantages
1. 5-inch high-definition touch screen, easy to operate and intuitive display;
2. Automatically identify 9 different rotors to eliminate potential safety hazards caused by user misoperation (Optional function);
3. It has 9 files of acceleration and10 files of deceleration level, which can effectively prevent secondary suspension and have a good centrifugal effect.
4. 15 groups of programs can be stored for users to use;
5. AC variable frequency motor, high speed control precision, imported environmental protection compressor;
6. There are various protections such as overspeed, door protection, imbalanceprotection, etc. to ensure the safety of human and machine;
7. Free switching of speed and RCF;
8. Low noise:the noise is close to silent at the highest speed;
9. Sealed rotor for effective protection against aerosol.
| Specifications | CFG-Mini15D |
| Max. Speed | 15000rpm(500-15000rpm), increment: 100rpm |
| Max. RCF | 15100×g, increment: 100×g |
| Speed Accuracy | ±20rpm |
| Rotor Capacity | 0.2mL/0.5mL/1.5mL/2mL×12 |
| Run Time | 30sec-99min/Continuous |
| Acceleration/Braking time | 11s↑/9s↓ |
| Driving Motor | Brushless DC motor |
| Safety Devices | Door interlock, Over-speed detection, Over-temperature detection, Automatic internal diagnosis |
| Power | Single-phase, AC100V-240V, 50Hz/60Hz, 3A 100W |
| Noise level | ≤54dB |
| Dimension[D×W×H] | 255mm×245mm×140mm |
| Weight | 6kg |
| Other functions | Speed/RCF switch, Short-time run function, sound-alert function |
CFG-14D Features
CFG-12D Features
| Specifications | CFG-14D | CFG-12D |
| Speed Range | 200-12000rpm, increment: 10rpm | 500-12000rpm, increment: 100rpm |
| Max. RCF | 13680×g | 13680×g |
| Speed Accuracy | ±20 | ±100 |
| Run Time | 30sec-99min/Continuous | 10sec-99min/Continuous |
| Motor | Brushless DC motor | Brushless DC motor |
| Display | LCD | LCD |
| Safety Devices | Door interlock, Overspeed detector; Automatic internal diagnosis, Automatic rotor identification | Door interlock |
| Acceleration/Braking time | 30s↑30s↓ | 40s↑40s↓ |
| Power | Single-phase, 200V-240V,50Hz/60Hz, 5A; 100V-120V,50Hz/60Hz, 5A 160W | Single-phase, 200V-240V,50Hz/60Hz, 5A; 380W |
| Dimension[W×D×H] | 280mm×364mm×274mm | 280mm×364mm×213mm |
| Weight | 10.5kg | 8.5kg |
| Advanced features | Speed/RCF switch; Short-time run function; sound-alert function | Speed/RCF switch; Short-time run function; sound-alert function |
Your dedicated partner in providing high-quality laboratory and research equipment. With years of industry experience, we specialize in supplying cutting-edge laboratory instruments, research equipment, and essential lab tools to support scientific discovery, educational advancement, and innovation across various industries.