SP-IUV8 and SP–IUV9 Double Beam UV Visible Spectrophotometer serve as the basic equipment for quality control, technical evaluation and scientific research, and can be widely used in susceptibility testing, medicine and health, biochemistry, environmental monitoring, commodity inspection, petrochemical and other fields.
Enable the host machine with excellent optical properties, metering performance, low stray light and noise, high metering accuracy and stability.
USB communication port.
Imported long-life deuterium lamp, imported OSRAM tungsten lamp.
Facilitate the light source to automatically switch to the best position, and allow users to operate the instrument, replace the light source and maintain the instrument more conveniently, accurately and safely.
Sophisticated hardware and software design.
Automatic scanning measurement spectrum, multi-wavelength (1 ~ 3λ) measurement, kinetic measurement, 1-3 curve fitting, 1-4 derivative spectra.
Spectra printing and storage and data analysis.
| Model | SP-IUV8 | SP-IUV9 |
| Photometry | Double beam | |
| Monochromator Type | Czerny-Turner | |
| Focal Length | 200mm | |
| Grating | 1600 lines/mm | |
| Detector | Silicon photocell | |
| Spectrum Bandwidth | 2nm or 1nm | 0.5nm,1nm,2nm,4nm,5nm |
| Wavelength Setting | 8-inch color touch-screen | |
| Wavelength Range | 190-1100nm | |
| Wavelength Accuracy | ±0.3nm | |
| Wavelength Repeatability | ≤0.1nm | |
| Scanning Speed | Fast-Medium-Slow | |
| Stray Light | ≤0.02%T( at 220nm NaI, 360nm NaNo2 ) | |
| Photometric Range | 0.0-200.0%T -0.301-4.000A 0.000-9999C | |
Photometric Accuracy | ±0.3%T ±0.002Abs (0-0.5A) ±0.004 Abs (0.5-1A) | |
| Photometric Repeatability | ≤0.15%T 0.001 Abs (0-0.5A) 0.002 Abs (0.5-1A) | |
| Baseline | ≤±0.0008 A(200-1090nm) | |
| Sound Emission | 100%(T)Sound emission≤0.1%(T) , 0%(T)Sound emission≤0.02%(T) | |
| Drifting | ≤0.004 Abs/h (250nm and 500nm after 2h warm up) | |
| COM Port | USB | |
| Light Source | Hamamatsu D2 lamp,Osram halogen tungsten lamp | |
| Electricity | AC220V±22V, 50Hz±1Hz, 200W | |
| N.W./G.W | 34/42.5kg | |
| Product Dimension(L*W*H) | 584*504*360mm | |
| Shipping Dimension(L*W*H) | 730*630*450mm | |
1、Applications
Ultrasonic Homogenizer is a multi-functional and multi-purpose instrument that uses strong ultrasound to produce cavitation effect in liquid and ultrasonically treat substances. It can be used for a variety of animal and plant cells and viruses. Cell disruption can also be used for emulsification, separation, extraction, defoaming, degassing, cleaning and accelerating chemical reactions, etc. It is used in the teaching, research and production of biochemistry, microbiology, medicinal chemistry, surface chemistry, physics, zoology, agronomy, pharmacy and other fields.
、Features
1. Full-featured, beautiful appearance, reliable performance, using the latest single-chip technology + 4.3-inch TFT capacitive touch screen control (7-inch optional), optional computer communication or data printing functions.
2. High degree of intelligence, central microcomputer centralized control, ultrasonic time, power can be set from 1%-100%.
3. Sample temperature detection and display, frequency microcomputer automatic tracking, automatic fault alarm.
4. Supporting Alcoa 7075 transducer + a set of high-purity titanium alloy horns, industrial horns can continuously achieve ultrasound for more than one hour (only high-purity titanium alloys can be achieved).
5. With overload protection function and the horn is not immersed in liquid, it will automatically protect the horn from damage.
6. It can realize the voice alarm function caused by malfunction, over-temperature or operation error, which is more humane.
3、Technical Parameters
Model | JY96-IIN |
Power | 1.5-150W Continuously adjustable |
Crushing capacity | 1.5-150ML( Need to match the corresponding horn ) |
Display method | True color capacitive touch screen display |
Single ultrasound time | 0.1-99.9S |
Single gap time | 0.1-99.9S |
Total time (ultrasound + gap) | 1-99H59M59S |
Frequency Range | 20-25KHz |
Temperature control range | 0-100 degrees (Optional low temperature and constant temperature) |
Alarm function | Time, overload, no load, over temperature |
Standard Horn | Φ6(mm) |
Duty cycle | 0.1-99.9% |
Data storage | 20 groups |
Power supply (optional 110V) | 220V/110V/ 50Hz/60Hz |
Net size of the instrument (D*W*H) | 410*225*290(mm) |
Ultrasonic host net weight | 12kg |
Ultrasonic host gross weight | 16kg |
Host packaging (length * width * height) | 470*305*430(mm) |
Gross weight of soundproof box | 10kg |
Outer packing of soundproof box (length * width * height) | 350*350*550(mm) |
way to control | Microcontroller + TFT touch |
Optional function | Computer communication + data printing + soundproof box lighting or sterilization |
Voice alarm and prompt function | Yes |
Brief Introduction
SP-LF97 fluorescence spectrophotometer is a new generation of high performance molecular luminescence analysis instrument. The Pduct structure is exquisite, has the characteristics of high detection sensitivity, fast scanning speed, wide spectrum measuring range, high dynamic range, fast 3D scanning, and so on. Easily meet the requirements in the field of material research, pharmaceutical analysis, biochemical and clinical testing, water quality analysis and control, food safety testing (dairy Pducts, aquatic Pducts, such as vitamin C, selenium, aflatoxin), and other areas.
Main Features
High sensitivity: based on high efficiency optical design and weak signal detection technology, the water Raman peak signal to noise ratio can be greater than 200 (P – P) to the leading domestic and international advanced level.
High scanning speed: the high speed digital signal Pcessing unit Pvides the world’s fastest scanning speed at 48000nm/min. Only 1 second to get classic fluorescence spectra, 1 minute to get high quality of three-dimensional fluorescence spectra.
Wide Spectral measurement range: using a double monochromator design, excitation and emission wavelength range covering 200nm to 900nm, meet the needs of most fluorescence analysis.
Excitation light path monitoring system: instrument is equipped with excitation light dual beam ratio monitoring system to ensure the fluorescence signal high and stable.
High quality assurance: using Hamamatsu’s high quality Xenon light source and photoelectric multiplier tube detectors and instruments to Pvide sufficient light intensity signal and the detection sensitivity.
Built-in optical gate: Built-in optical gate, designed for unstable sample
| Model | SP-LF97 | SP-LF97XP | SP-LF97PRO |
| Excitation Source | 150W xenon lamp(Hamamatsu) | ||
| Excitation Wavelength | 200nm~900nm | ||
| Emission Wavelength | 200nm~900nm | ||
| Excitation Slit | 10nm | 2nm、5nm、10nm、20nm | |
| Emission Slit | 10nm | 2nm、5nm、10nm、20nm | |
| Wavelength Accuracy | ±1.0nm | ±0.4nm | ±1.0nm |
| Wavelength Repeatability | ≤0.5nm | ≤0.2nm | ≤0.5nm |
| Signal-to-Noise Ratio | S/N≥150(10nm Slit)(P-P) S/N≥1000(10nm Slit)(RMS) S/N≥10000(10nm Slit)(RMSBG) | S/N≥200(10nm Slit)(P-P) S/N≥1200(10nm Slit)(RMS) S/N≥12000(10nm Slit)(RMSBG) | S/N≥150(10nm Slit)(P-P) S/N≥1000(10nm Slit)(RMS) S/N≥10000(10nm Slit)(RMSBG) |
| Limit | ≤1×10-10 g/ml(Quinine Sulfate Solution) | ≤5×10-11 g/ml(Quinine Sulfate Solution) | ≤1×10-10 g/ml(Quinine Sulfate Solution) |
| Linearity | γ≥0.995 | ||
| Peak Repeatability | ≤1.5% | ||
| Stability(10min) | Zero Drift: ±0.3 | ||
| Value Limit: ±1.5% | |||
| Wavelength Scan Speed | Multi-speed Level, Maximum at 48000nm/min | ||
| Photometric Quantity Range | 0.00-10000.00 | ||
| Data Transmission | USB2.0 | ||
| Power | 200W | ||
| Power Source | 110-240V AC.50/60Hz | ||
| Instrument Dimension | 380×445×310(mm) | ||
| Weight | Net Weight: 12kg, Gross Weight: 14kg | ||
Optional Parts
| Accessories | Functions |
| Single sample rack | Conventional liquid fluorescence sample |
| Multi purpose fluorescent sample rack holder | Base holder for other racks |
| Octave Filters | Remove the interference of frequency doubling |
| Membrane sample rack | For membrane sample |
| Powder sample rack | For powder samples |
| Auto Polarization filter | Adjust the polarization light |
1. Simple operation, no sample pre-treatment, no sample destruction.
2. 900nm-2500nm ultra-wide spectral range, fast analysis speed. Multiple component indicators can be detected simultaneously within 1 minute, such as moisture, fat, protein, and amino acids.
3. The core main parts are all international well-known brands.
4. Built-in high-quality PTFE reference module and polystyrene wavelength standard film, automatic reference correction and wavelength monitoring, to ensure accurate and stable measurement results.
5. Equipped with integrating sphere diffuse reflection system, large sampling spot and sample rotating table to ensure the reproduction effect of uneven samples.
6. Good model transfer can be carried out between multiple instruments. Each instrument is calibrated, identified and verified in strict accordance with industry recommendations. All tests use NIST traceable standards.
7. A variety of sample cups and accessories can be selected to meet the test of particles, powders, liquids and films.
8. The instrument monitors the environmental temperature and humidity in real time and stores it in the spectrum file, which is convenient for users to consult and optimize the measurement conditions.
9. Simple operation, intuitive user interface, and the authority management function can meet the needs of different occasions.
10. Combined with China Agricultural University’s Near Infrared Spectroscopy Analysis Software (CAUNIRS), an authoritative professional NIR quantitative and qualitative analysis model can be established. Compact instrument structure and open working platform, easy for cleaning.
Convenient and easy to use
1. Simple operation control
No chemical reagents, no pre-treatment, directly put the sample into the sample cup. Simple operation, with a single tap, the experiment can be completed quickly, which avoid test errors caused by operation. Built-in background, no manual operation, the influence of human interference is eliminated.
2. Friendly interface software
Simple operation, intuitive interface, and the function is powerful. It contains comprehensive and extensive data collection, preprocessing, evaluation and other functions, and the required installation package can be configured to meet actual needs. The functions of “User Settings” and “User Management” have also been expanded to facilitate users to customize the operator’s use authority.
3. Convenient maintenance
The structure of the instrument is compact and exquisite, and the working platform is easy to clean. The consumables (light source and desiccant) are designed for long-life, but if they need to be replaced, the user can quickly complete the replacement in a short time without opening the instrument.
Personalized function
1. Model establishment and optimization
Adopting the near-infrared spectroscopy software (CAUNIRS) developed by China Agricultural University, this software integrates a variety of modeling methods and powerful data preprocessing functions, with powerful model editing, calculation, evaluation, and optimization functions, which can be easily and quickly provided for users Establish an authoritative and professional near-infrared quantitative analysis model or qualitative identification analysis model, and follow-up model maintenance services.
2. Model delivery
The ultra-high accuracy and stability of the instrument ensure that the models between multiple instruments can be easily transferred, and resource sharing is realized.
3. Instrument calibration
The built-in standard material of the instrument is controlled by the Prolab S450 software, which automatically completes the self-test of the instrument’s performance, and provides indicators and evaluations of the instrument’s performance to ensure that the instrument is operating normally and standardized.
According to the actual verification needs of users, the company can also provide a complete set of quality standard verification materials, and customize verification procedures through Prolab SP-LIF450 to meet different verification needs.
Meet the audit standards of the enterprise, and are recognized as the most professional supplier of spectrometers, and provide each user with a complete set of instrument certification information.
4. Perfect service
The company has a multi-dimensional service team with instrument development and complete technology, which can help users familiarize themselves with the use of sampling accessories, the selection of optical components, and software operations. It can also be tailored to provide users with solutions according to their needs. In addition, it has established application laboratories in cooperation with many domestic universities and research institutes, responsible for user method development, technical training, and information consultation.
The company owns experienced maintenance engineers to provide the most professional installation and commissioning and high-level after-sales service for users across the country to meet the needs of every user.
1, High configuration of hardware: 7 inches TFT Color Capacitive Touch-screen Display; Bluetooth 2.1; Concave Grating.
2, Double Array 256 Image Element CMOS Sensor; Long life-span stable xenon lamp.
3, With reflective and transmissive spectrum, accurate Lab value, good to calculate color formula and do precise color transmission.
4, Auto identify measuring aperture. Freely switchable between 3 measuring apertures: Φ 25.4mm/8mm/4mm. Users also can customize apertures.
5, Built-in temperature sensor to monitor and compensate the measuring temperature to ensure the measurement more precision.
6, Wavelength range 360nm – 780nm. Built-in 400nm cut off, more professional in UV measurement.
7, Independent light source detector, continuously monitor the condition of light sources to ensure the light source reliable.
8, Multiple measurement modes: Quality Management Mode, Sample Mode; Meet more users’ requirement.
9,A variety of optional accessories: Reflection sample holding tool, transmission fixture, micro 4mm aperture transmission test components, instrument inversion test components, applicable to more working conditions.
10, Big capacity data storage, for 20000 pieces test result.
11, Built-in camera locating.
12, More powerful extended functions at the PC software.
Application Industry
SP-CLR602 benchtop spectrophotometer is used to do precise color analysis and transmission in laboratories. It can be widely applied in different industries, such as plastics, electronics, paint and ink, printing, garments, leather, paper, auto, medical, cosmetics, food, science institutes, laboratories.
| Model | SP-CLR602(Pulsed xenon lamp) |
| Optical Geometry | Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle); |
| SCI (specular component included)/SCE (specular component excluded);Include UV / excluded UV light source; | |
| Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing); | |
| SCI (specular component included)/SCE (specular component excluded);Include UV / excluded UV light source; | |
| Haze(ASTM D1003); | |
| Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 | |
| Integrating Sphere Size | Φ 154mm |
| Light Source Device | 360nm-780nm Xenon Lamp, 400nm cut-off Xenon Lamp |
| Spectrophotometric Mode | Concave Grating |
| Sensor | 256 Image Element Double Array CMOS Image Sensor |
| Wavelength Range | 360-780nm |
| Wavelength Pitch | 10nm |
| Semiband Width | 5nm |
| Reflectance Range | 0~200% |
| Measuring Aperture | Reflective: Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; |
| Transmissive: Φ30mm/Φ25.4mm; Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position | |
| Specular Component | Reflectance: SCI&SCE |
| Transmittance: SCI&SCE | |
| Color Space | CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter LAB, Munsell, s-RGB, HunterLab, DIN, βxy |
| Color Difference Formula | ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00v, ΔE(Hunter), DIN ΔE99 |
| Colorimetric Index | WI (ASTM E313, CIE/ISO, AATCC, Hunter), |
| YI (ASTM D1925, ASTM 313), | |
| MI (Metamerism Index), | |
| Staining Fastness, Color Fastness, Color Strength, Opacity, | |
| Gardner Index, Pt-Co Index, 555 Index, Haze(ASTM D1003),Saybolt | |
| Observer Angle | 2° & 10° |
| Illuminants | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30 |
| Displayed Data | Spectrogram/Values, Chromaticity Values, Color Difference Values/Graph, Pass/Fail Result, Color Offset |
| Measuring Time | About 2.4s (Measure SCI & SCE about 5s) |
| Repeatability | Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.07% (400 nm to 700 nm: within 0.06%) |
| Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.015 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) | |
| Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.07% (400 nm to 700 nm: within 0.07%) | |
| Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.018 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) | |
| Inter-instrument Error | Φ25.4mm/SCI, Within ΔE*ab 0.15 |
| (Average for 12 BCRA Series II color tiles) | |
| Size | 370×300×200mm |
| Weight | About 9.6kg |
| Power Supply | DC 24V, 3A Power Adapter |
| Light Source Device Life | 5 years, more than 3 million times measurements. |
| Display | 7″ TFT Capacitive Screen-touch Display |
| Data Port | USB & Print serial port |
| Data Storage | Standard 2000 Pcs, Sample 20000 Pcs |
| Language | Simplified Chinese, Traditional Chinese, English, |
| Working Environment | Temperature: 0~40℃; Humidity: 0~85% (No Condensation) |
| Storage Environment | Temperature: -20~50℃; Humidity: 0~85% (No Condensation) |
| Standard Accessory | Power Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 8 caliber, 4 caliber, |
| Optional Accessory | Micro-printer, Transmissive Test Clamp Component,Micro Aperture(4mm) transmission test clamp component, Instrument inversion components,culture dish |
| Notes: The specifications are subject to change without notice. | |
1. Simple operation, no sample pre-treatment, no sample destruction.
2. 900nm-2500nm ultra-wide spectral range, fast analysis speed. Multiple component indicators can be detected simultaneously within 1 minute, such as moisture, fat, protein, and amino acids.
3. The core main parts are all international well-known brands.
4. Built-in high-quality PTFE reference module and polystyrene wavelength standard film, automatic reference correction and wavelength monitoring, to ensure accurate and stable measurement results.
5. Equipped with integrating sphere diffuse reflection system, large sampling spot and sample rotating table to ensure the reproduction effect of uneven samples.
6. Good model transfer can be carried out between multiple instruments. Each instrument is calibrated, identified and verified in strict accordance with industry recommendations. All tests use NIST traceable standards.
7. A variety of sample cups and accessories can be selected to meet the test of particles, powders, liquids and films.
8. The instrument monitors the environmental temperature and humidity in real time and stores it in the spectrum file, which is convenient for users to consult and optimize the measurement conditions.
9. Simple operation, intuitive user interface, and the authority management function can meet the needs of different occasions.
10. Combined with China Agricultural University’s Near Infrared Spectroscopy Analysis Software (CAUNIRS), an authoritative professional NIR quantitative and qualitative analysis model can be established. Compact instrument structure and open working platform, easy for cleaning.
Convenient and easy to use
1. Simple operation control
No chemical reagents, no pre-treatment, directly put the sample into the sample cup. Simple operation, with a single tap, the experiment can be completed quickly, which avoid test errors caused by operation. Built-in background, no manual operation, the influence of human interference is eliminated.
2. Friendly interface software
Simple operation, intuitive interface, and the function is powerful. It contains comprehensive and extensive data collection, preprocessing, evaluation and other functions, and the required installation package can be configured to meet actual needs. The functions of “User Settings” and “User Management” have also been expanded to facilitate users to customize the operator’s use authority.
3. Convenient maintenance
The structure of the instrument is compact and exquisite, and the working platform is easy to clean. The consumables (light source and desiccant) are designed for long-life, but if they need to be replaced, the user can quickly complete the replacement in a short time without opening the instrument.
Personalized function
1. Model establishment and optimization
Adopting the near-infrared spectroscopy software (CAUNIRS) developed by China Agricultural University, this software integrates a variety of modeling methods and powerful data preprocessing functions, with powerful model editing, calculation, evaluation, and optimization functions, which can be easily and quickly provided for users Establish an authoritative and professional near-infrared quantitative analysis model or qualitative identification analysis model, and follow-up model maintenance services.
2. Model delivery
The ultra-high accuracy and stability of the instrument ensure that the models between multiple instruments can be easily transferred, and resource sharing is realized.
3. Instrument calibration
The built-in standard material of the instrument is controlled by the Prolab S450 software, which automatically completes the self-test of the instrument’s performance, and provides indicators and evaluations of the instrument’s performance to ensure that the instrument is operating normally and standardized.
According to the actual verification needs of users, the company can also provide a complete set of quality standard verification materials, and customize verification procedures through Prolab SP-LIF450 to meet different verification needs.
Meet the audit standards of the enterprise, and are recognized as the most professional supplier of spectrometers, and provide each user with a complete set of instrument certification information.
4. Perfect service
The company has a multi-dimensional service team with instrument development and complete technology, which can help users familiarize themselves with the use of sampling accessories, the selection of optical components, and software operations. It can also be tailored to provide users with solutions according to their needs. In addition, it has established application laboratories in cooperation with many domestic universities and research institutes, responsible for user method development, technical training, and information consultation.
The company owns experienced maintenance engineers to provide the most professional installation and commissioning and high-level after-sales service for users across the country to meet the needs of every user.
The BEP-M600L Benchtop Multi-parameter Analyzer adopts a multi-purpose measurement method, which is suitable for the fields of health disease control, environmental protection, biological agriculture and forestry, water quality analysis, scientific research and institutions of higher learning.
General Features
pH
Ion
Conductivity
DO
| Model | BEP-M600L | |
| Parameters | pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation) | |
| pH | Range | -2.000 to 20.000 pH |
| Resolution | 0.1, 0.01, 0.001pH | |
| Accuracy | ±0.002 pH | |
| Calibration Points | Up to 6 | |
| Standard Customization | Yes | |
| Calibration Reminder | Yes | |
| Standard Recognition | NIST, GB, DIN buffers | |
| Slope Limit | Yes | |
| mV/ORP | Range | -2000.00 to 2000.00 mV |
| Resolution | 0.1, 0.01 mV | |
| Accuracy | ±0.03% FS | |
| EH ORP Mode | Yes | |
| ORP Calibration Points | 1~2 custom point (relative mV) | |
| pX | Range | -2.000 to 20.000 pX |
| Resolution | 0.1, 0.01, 0.001 pX | |
| Accuracy | ±0.002 pX | |
| Calibration Points | Up to 6 | |
| ISE | Range | 1.000E-9 to 9.999E9 |
| Units | mol/L, mmol/L, g/L, mg/L, μg/L | |
| Resolution | Up to 4 significant digits | |
| Accuracy | ±0.3% | |
| Calibration Points | Up to 6 | |
| Conductivity | Range | 0.000 μS/cm to 3000 mS/cm |
| Resolution | 0.001 μS/cm minimum, various with range selection | |
| Accuracy | ±0.5% FS | |
| Reference Temperature | 5, 10, 15, 18, 20, 25 ºC | |
| Calibration Points | Up to 5 | |
| Standard Recognition | 146.5μS/cm, 1408μS/cm, 12.85mS/cm, 111.3mS/cm | |
| Resistivity | Range | 5.00 Ω·cm~100.00 MΩ·cm |
| Resolution | 0.01 Ω·cm minimum | |
| Accuracy | ±0.5% FS | |
| TDS | Range | 0.000 mg/L~1000 g/L |
| Resolution | 0.001ppm minimum, changed with range | |
| Accuracy | ±0.5%FS | |
| Salinity | Type | NaCl% |
| Range | (0.00~8.00)% | |
| Resolution | 0.01% | |
| Accuracy | ±0.1% | |
| Dissolved | Range | 0.00 to 99.99 mg/L |
| Oxygen Concentration – Polarographic | Resolution | 0.01 mg/L |
| Accuracy | ±0.1 mg/L | |
| Calibration Reminder | Yes | |
| Calibration Points | Air-saturated water or zero point | |
| Barometric Compensation | Yes | |
| Manual Salinity Factor Correction | Yes | |
| % Saturation -Polarographic | Range | (0.0 to 600)% |
| Resolution | 0.10% | |
| Accuracy | ±2.0% | |
| Temperature | Range | -5 to 130 ºC |
| Unit | ºC | |
| Resolution | 0.1 | |
| Accuracy | ±0.1 | |
| Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
| Reading Prompts | Reading, Stable, Locked | |
| Temp. Compensation | ATC, MTC | |
| Data management | Data Storage | 1000 Groups |
| GLP Features | Yes | |
| Log Management | Yes | |
| Inputs | pH Electrode | BNC(Q9) |
| DO with Temp. Probe | 6-pin Mini-DIN | |
| Conductivity with Temp. Probe | 8-pin Mini-DIN | |
| Outputs | USB, RS 232 | USB 2.0 flash memory device, printer, PC |
| Display options | Backlight | Yes |
| Auto Shutdown | 1~60 min, off | |
| IP Rating | IP54 | |
| Date and Time | Yes | |
| General | Electricity | AC Adapter, 100-240V AC input, DC24V output |
| Dimensions | 280×280×130 mm | |
| Weight | 2500g | |
PH measurement has a wide range of applications. It is now widely used in colleges, environmental protection, medicine, food, health, geological exploration, metallurgy, marine exploration and other fields. PH measurement is required for common acid rain detection, surface water, industrial wastewater, drinking water, beverages, daily chemical products, textiles, etc.
Advantages
| Model | PH-B500T | |
| Parameters | pH/Temp.(mV/ORP) | |
| pH | Range | -2.000 to 20.000 pH |
| Resolution | 0.1, 0.01, 0.001pH | |
| Accuracy | ±0.002 pH | |
| Calibration Points | Up to 6 | |
| Standard Customization | Yes | |
| Calibration Reminder | Yes | |
| Standard Recognition | NIST, GB, DIN, USA, MERK, JIS buffers | |
| Slope Limit | Yes | |
| mV/ORP | Range | -2000.00 to 2000.00 mV |
| Resolution | 0.1, 0.01 mV | |
| Accuracy | ±0.1 mV or ±0.03% | |
| EH ORP Mode | Yes | |
| ORP Calibration Points | 1 custom point (relative mV) | |
| Temperature | Range | -10 to 135 ºC, 14 to 275 ºF |
| Unit | ºC, ºF | |
| Resolution | 0.1 | |
| Accuracy | ±0.1 | |
| Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
| Reading Prompts | Reading, Stable, Locked | |
| Temp. Compensation | ATC, MTC | |
| Data management | Data Storage | 1000 Groups |
| GLP Features | Yes | |
| Log Management | Yes | |
| Inputs | pH Electrode | BNC(Q9) |
| Temp. Probe | 4-pin aviation connector | |
| Outputs | USB | USB 2.0 flash memory device, PC |
| RS 232 | printer, scanner, auto-sampler | |
| Display options | Backlight | Yes |
| Auto Shutdown | 1~60 min, off | |
| IP Rating | IP54 | |
| Date and Time | Yes | |
| General | Electricity | AC Adapter, 100-240V AC input, DC24V output |
| Dimensions | 220×195×68 mm | |
| Weight | 950g | |
The conductivity meter is a water quality analysis instrument developed for high-end water quality management and automatic control of medical multi-effect distilled water systems, boiler bottom water, condensate water, and heat exchange systems operating in higher temperature environment.
Advantages
| Model | CON-B400F | |
| Conductivity | Range | 0.000 μS/cm to 1000 mS/cm |
| Resolution | 0.001 μS/cm minimum,
various with range selection | |
| Accuracy | ±0.5% FS | |
| Reference Temperature | 20, 25 ºC | |
| Calibration Points | Up to 3 | |
| Standard Recognition | 84μS/cm, 1413μS/cm, 12.88mS/cm | |
| Resistivity | Range | 5.00 Ω·cm~100.00 MΩ·cm |
| Resolution | 0.01 Ω·cm minimum | |
| Accuracy | ±0.5% FS | |
| TDS | Range | 0.00ppm~1000ppt |
| Resolution | 0.001 ppm minimum, various with range selection | |
| Accuracy | ±0.5% FS | |
| Salinity | Range | 0.0~80.0 ppt |
| Resolution | 0.1 ppt | |
| Accuracy | ±1 ppt | |
| Temperature | Range | -10 to 135 ºC, 14 to 275 ºF |
| Unit | ºC, ºF | |
| Resolution | 0.1 | |
| Accuracy | ±0.1 | |
| Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
| Reading Prompts | Reading, Stable, Locked | |
| Temp. Compensation | ATC, MTC | |
| Data management | Data Storage | 500 results each |
| GLP Features | Yes | |
| Conductivity with Temp. Probe | 5-pin aviation connector | |
| Outputs | USB | USB 2.0 flash memory device, PC |
| RS 232 | printer | |
| Display options | Backlight | Yes |
| Auto Shutdown | 1~60 min, off | |
| IP Rating | IP54 | |
| Date and Time | Yes | |
| General | Electricity | AC Adapter, 100-240V AC input, DC9V output |
| Dimensions | 242×195×68 mm | |
| Package Dimension (W*D*H) | 360*300*240mm | |
| N.W. / G.W. | 900g / 2.6 kg | |
The dissolved oxygen meter has automatic temperature compensation function, as well as air pressure and salinity compensation functions, which are suitable for various fields.
Advantages
| Model | DO-B500T | |
| Parameters | DO/Temp(DO Saturation). | |
| Dissolved
Oxygen Concentration | Sensor Type | Polarographic |
| Range | 0.00 to 99.99 ppm | |
| Resolution | 0.01 ppm | |
| Accuracy | ±0.10ppm, 0.00~50.00ppm
±0.50ppm, 50.0~99.99ppm | |
| Calibration Reminder | Yes | |
| Calibration Points | Air-saturated water or zero point | |
| Barometric Compensation | Yes | |
| Manual Salinity Factor Correction | Yes | |
| DO Saturation | Range | (0.0 to 600)% |
| Resolution | 0.10% | |
| Accuracy | ±2.0% | |
| Temperature | Range | -10 to 135 ºC, 14 to 275 ºF |
| Unit | ºC, ºF | |
| Resolution | 0.1 | |
| Accuracy | ±0.1 | |
| Measurement | Reading Mode | Auto-Read (Fast, Medium, Slow), Timed, Continuous |
| Reading Prompts | Reading, Stable, Locked | |
| Temp. Compensation | ATC, MTC | |
| Data management | Data Storage | 1000 Groups |
| GLP Features | Yes | |
| Log Management | Yes | |
| Inputs | DO with Temp. Probe | 4-pin aviation connector |
| Outputs | USB | USB 2.0 flash memory device, PC |
| RS 232 | printer, scanner, auto-sampler | |
| Display options | Backlight | Yes |
| Auto Shutdown | 1~60 min, off | |
| IP Rating | IP54 | |
| Date and Time | Yes | |
| General | Electricity | AC Adapter, 100-240V AC input, DC24V output |
| Dimensions | 220 x 195 x 68 mm | |
| Weight | 950g | |
The BEP-M500T Benchtop Multi-parameter Analyzer a multi-purpose measurement method, which is suitable for the fields of health disease control, environmental protection, biological agriculture and forestry, water quality analysis, scientific research and institutions of higher learning.
General Features
pH
Ion
Conductivity
DO
| Model | BEP-M500T | |
| Parameters | pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation) | |
| pH | Range | -2.000 to 20.000 pH |
| Resolution | 0.1, 0.01, 0.001pH | |
| Accuracy | ±0.002 pH | |
| Calibration Points | Up to 6 | |
| Standard Customization | Yes | |
| Calibration Reminder | Yes | |
| Standard Recognition | NIST, GB, DIN, USA, MERK, JIS buffers | |
| Slope Limit | Yes | |
| mV/ORP | Range | -2000.00 to 2000.00 mV |
| Resolution | 0.1, 0.01 mV | |
| Accuracy | ±0.1 mV or ±0.03% of
reading whichever is greater | |
| EH ORP Mode | Yes | |
| ORP Calibration Points | 1 custom point (relative mV) | |
| pX | Range | -2.000 to 20.000 pX |
| Resolution | 0.1, 0.01, 0.001 pX | |
| Accuracy | ±0.002 pX | |
| Calibration Points | Up to 6 | |
| ISE | Range | 1E-9 to 9.999E9 |
| Units | mol/L, mmol/L, g/L, mg/L, μg/L, ppm | |
| Resolution | Up to 4 significant digits | |
| Accuracy | ±0.3% | |
| Calibration Points | Up to 6 | |
| Conductivity | Range | 0.000 μS/cm to 2000 mS/cm |
| Resolution | 0.001 μS/cm minimum,
various with range selection | |
| Accuracy | ±0.5% FS | |
| Reference Temperature | 5, 10, 15, 18, 20, 25 ºC | |
| Calibration Points | Up to 5 | |
| Calibration Reminder | Yes | |
| Standard Recognition | 10 μS/cm, 84 μS/cm, 500 μS/cm, 1413 μS/cm, 12.88 mS/cm | |
| Resistivity | Range | 5.00 Ω·cm~100.00 MΩ·cm |
| Resolution | 0.01 Ω·cm minimum | |
| Accuracy | ±0.5% FS | |
| TDS | Range | 0.000~1000 ppt |
| Resolution | 0.001 ppm minimum, changed with range | |
| Accuracy | ±0.5%FS | |
| Salinity | Type | NaCl |
| Range | 0.0~80.0ppt | |
| Resolution | 0.1ppt | |
| Accuracy | ±1ppt | |
| Dissolved
Oxygen Concentration – Polarographic | Range | 0.00 to 99.99 ppm |
| Resolution | 0.01 ppm | |
| Accuracy | 0.10ppm, 0.00~50.00ppm
±0.50ppm, 50.0~99.99ppm | |
| Calibration Reminder | Yes | |
| Calibration Points | Air-saturated water or zero point | |
| Barometric Compensation | Yes | |
| Manual Salinity Factor Correction | Yes | |
| % Saturation -Polarographic | Range | (0.0 to 600)% |
| Resolution | 0.10% | |
| Accuracy | ±2.0% | |
| Temperature | Range | -10 to 135 ºC, 14 to 275 ºF |
| Unit | ºC, ºF | |
| Resolution | 0.1 | |
| Accuracy | ±0.1 | |
| Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
| Reading Prompts | Reading, Stable, Locked | |
| Temp. Compensation | ATC, MTC | |
| Data management | Data Storage | 1000 Groups |
| GLP Features | Yes | |
| Log Management | Yes | |
| Inputs | pH Electrode | BNC(Q9) |
| DO with Temp. Probe | 4-pin aviation connector | |
| Conductivity with Temp. Probe | 5-pin aviation connector | |
| Outputs | USB | USB 2.0 flash memory device, PC |
| RS 232 | printer, scanner, auto-sampler | |
| Display options | Backlight | Yes |
| Auto Shutdown | 1~60 min, off | |
| IP Rating | IP54 | |
| Date and Time | Yes | |
| General | Electricity | AC Adapter, 100-240V AC input, DC24V output |
| Dimensions | 220×195×68 mm | |
| Weight | 950g | |
The BEP-M310T Portable Multi-parameter Analyzer adopts a multi-purpose measurement method, which is suitable for the fields of health disease control, environmental protection, biological agriculture and forestry, water quality analysis, scientific research and institutions of higher learning.
General Features
pH
Ion
Conductivity
DO
Compared with indicator titration, potentiometric titration has the advantages of objective reliability, high accuracy, easy automation, and is not limited by the color and turbidity of the solution. It is an important analytical method.
According to the indication principle and the chemical reaction that occurs, the indication methods often used in titration analysis can be generally classified into: potentiometric titration, coulomb titration, permanent stop titration, conductometric titration, photometric titration, and temperature titration.
| Model | TITR-A50 | |
| Burette | Titrimetric Repeatability | 0.20% |
| Accuracy | 10ml Burette: ±0.025ml 20ml Burette: ±0.035ml | |
| Resolution | 10ml Burette: 0.33μl 20ml Burette: 0.66μl | |
| Mechanical Unit | Resolution | 1/30000 |
| Measuring Unit | Range | (-1999.0 ~ 1999.0) mv, (0.00 ~ 14.00)pH |
| Resolutions | 0.1mV, 0.01pH | |
| Accuracy | pH: ±0.01pH, mv: ±0.03%FS | |
| Fluctuation | (±0.3mV±1bit) /3h | |
| Temp. Compensation | Range | (-5.0 ~ 105.0) ℃ |
| Resolutions | 0.1 ℃ | |
| Accuracy | ±0.3 ℃ | |
| General | Electricity | AC Adapter, 100-240V AC input, DC24V output |
| Dimension (mm)& Weight (kg) | 340×400×400, 10 | |
| Package Dimension(mm)& G.W. (kg) | W550×D510×H500
11.5 | |
The moisture analyzer can be widely used in all industries that need to quickly measure moisture. It can measure the moisture content of various samples such as solids, granules, powders, colloids and liquids to meet the requirements of laboratory and production processes in various industries. Rapid determination of content.
Features
| Model | BA-M500 |
| Weighing range | 0-220g |
| Weighing accuracy | 0.005g(5mg) |
| Moisture readability | 0.01% |
| Temperature range | Start -225℃ |
| Moisture measurement range | 0.01~100% |
| Weighing sensor | Imported PW series sensor |
| Heating light source | Tungsten halogen ring heating light source |
| Heating mode | Fast |
| Test mode | Automatic, timed, manual, stage |
| Timing time range | 1-360min (expandable) |
| Display parameters | Moisture %, solid content %, moisture curve, solid content curve, temperature curve; test duration, constant weight time, measurement mode, set temperature, measurement temperature, initial weight value, final weight value |
| Display language | English |
| Data storage | Store the latest 50 sets of measurement data (expandable) |
| Display curve | Simultaneously display three test curves (including moisture M, weight W, temperature T) |
| Sample pan dimension | Diameter:100 (mm) |
| Display | 7 inch capacitive touch display |
| Product dimensions (L*W*H) | 390*220*170 mm |
| Package Dimension (W*D*H)(mm) | 480*290*270 mm |
| Product net weight | 3.65 kg |
| G.W.(kg) | 6 kg |
1.Halogen lamp/HBM sensor
2.Aluminum shell/Stainless steel chamber
3.LCD(White back light with black font)
4.Temperature/Time set
5.The percentage of moisture content/dry residual
6.Store historical set
7.Option:Aluminum box/Printer/Grinder
SPECIFICATIONS
| Model | MCA110-10 | MCA110-5 | MCA110-2 | MCA110-1A |
| Capacity | 110g | |||
| Readability | 0.01g | 0.005g | 0.002g | 0.001g |
| Operating Temp | 5℃-35℃ | |||
| Display | Backlit LCD | High Definition Backlit LCD | ||
| Calibration | External Calibration | |||
| Interface | RS232(Standard)/USB(Option) | |||
| Pan Size | Ø90mm | |||
| Packing Size | 500*460*370mm | |||
| Gross Weight | 7.1kg | |||
| Heating Source | Halogen Lamp-1 | Halogen Lamp-2 | ||
| Temp. Sensor | PT100 | |||
| Temp. Range | 40℃-199℃ | |||
| Temp. Step | 1℃ | |||
| Moisture Range | 0.00%-100.00% | |||
| Moisture Readability | 0.20% | 0.10% | 0.04% | 0.01% |
| Dry Range | 100.00%-0.00% | |||
| Dry Readability | 0.20% | 0.10% | 0.04% | 0.01% |
| Temp Setting | 40℃-199℃ By 1℃ Step | |||
| Time Setting | 1-99min By 10s | |||
| Number of Storage | 15 | |||
| Heater | 220V ±15% 50Hz/110V±15% 60Hz/400W | |||
| Balance | Input: 220V 50Hz/110V 60HZ Output: 9V | |||
| Chamber Height | 22mm | |||
Karl Fischer moisture measurement method has been recognized as the most accurate method by many international standards, such as ISO, ASTM, DIN, BS, and JIS. This method is suitable for the determination of moisture content of various substances.Therefore, Karl Fischer moisture analyzers applying its principle have a wide range of applications for solid, liquid and gas samples.
GENERAL FEATURES
Volumetric Karl Fischer Titration
Coulometric Karl Fischer Titration
| Model | TITR-40VC | |
| Volumetric Titration | Range | (0.1mg~250)mg, |
| Polarization Current Accuracy | 1μA±0.2μA; 50μA±10μA | |
| Repeatability | ±0.5% | |
| Coulometric Titration | Range | 10μg~20mg |
| Polarization Current Accuracy | 1μA±0.2μA; 50μA±10μA | |
| Working Current | 1, 1.86, 5, 10μg (H2O)/S | |
| Accuracy | ± (5%+3) μg | |
| Repeatability | RSD of 100μg sample measurement result ≤3% | |
| General | Electricity | AC Adapter, 100-240 V AC input |
| Dimension (mm) & Weight (kg) | 340×400×400; 10 | |
It has the advantages of high measurement accuracy, good repeatability, and low test cost. It is widely used in petroleum, chemical, pharmaceutical, electric power, scientific research, and education sectors, and can be used to measure trace moisture in various liquids, solids, and gases.
| Model | TITR-K5 |
| Measurement Method | Karl Fischer Coulomb Method |
| Display Measurement Range | 0.1μg water—9999.9999mg water |
| Water Content Range | 0.0000001%-100% (the min. resolution of the printed result is 0.0001%) or 0.001ppm—106ppm |
| Resolution | 0.1μg water |
| Display | LCD color 7-inch large screen display |
| Accuracy | When the water content is 3-1000μg water, the error of the measured value is ≤±2μg;
When the water content is above 1000μg water, the error of the measured value is ≤±0.2% (excluding the error of sampling) |
| End Point Indication | Screen display/sound warning/printout/end point light prompt |
| Blank Processing | The blank current microprocessor automatically controls the compensation to ensure that the blank can be accurately deducted within the sample enrichment time of 10 minutes. |
| Stirring Speed | Adjustable control |
| Drift Compensation | Automatic microprocessor control |
| Data Input | Touch screen operation |
| Sample No. | User defined |
| Electrolysis Speed | Peak value: 2.4 mg water/min |
| Electrolytic Current | 0-430mA |
| Storage | Can store historical data |
| Printing | Built-in thermal high-efficiency printer, 56mm paper width |
| Print Content | μg/ppm/percent content/formula/date and time |
| Display State | Real-time drawing of colored titration curves |
| Self-check Function | Automatic diagnosis of instrument faults |
| Calendar/Clock | Analysis time, date display and printout (not lost when power off) |
| Power Consumption | <100W |
| Electricity | 220V±10%,50Hz±2.5Hz |
| Use Environment | Temperature 5—40℃, humidity<85% |
| Optional Function | Automatic liquid filling and draining function |
| Dimension | 350*260*198mm |
| N.W./G.W. | 10kg/13kg |
| Shipping Dimension | 450*450*300mm |
Advanced Detector Design improves measurement limit&resolution.
Full built-in sampling system
Automatic&User-friendly one-key operation
Wet& dry sample dispersion system design
Perfect accuracy and precision guaranteed
PSA-2L2308A intelligent full automatic wet&dry laser particle size analyzer adopts laser diffraction theory(Mie and Fraunhofer diffraction), with its measure size from 0.01μm to 2000μm(dry 0.1μm-2000μm) that offers reliable and repeatable particle size analysis for a diverse range of applications. It uses dual-beam& multiple spectral detection systems and side light scatter test technology to significantly improve precision and performance of test. It’s a prior choice for industrial production quality control departments and research institutions.
Advantages
Automatic&User-friendly one-key operation
Wet and dry sample dispersion system Integrated Design.
Automatic&manual operation mode are designed to freely choose.
realize one key to switch
Good dispersion structure
Full built-in Sample dispersion system ensures precise test result.
Perfect accuracy and precision guaranteed
Advanced Detector Design enhances the accuracy and stability of test results
Instrument Software provides high precision data with 10Khz data acquisition time.
| Model | PSA-2L2308A | |
| Measurment Standard | ISO 13320-1:2009,GB/T19007-2016,Q/0100JWN001-2013 | |
| Compliance with 21 CFR Part 11 | ||
| Measurment Principle | Laser diffraction principle | |
| Analysis | Mie and Fraunhofer scattering | |
| Detector Arrangement | Log-spaced array, test angle from 0.015 degree to 145 degree | |
| Measurment Range | Wet:0.01μm-2000 μm Dry: 0.1μm-2000μm | |
| Silicon Photodetectors | Wet:127PCS Dry:100 PCS | |
| Accuracy error | Wet<1% Dry<1% (CRM D50) | |
| Repeatability error | Wet<1% Dry<1% (CRM D50) | |
| Light sourceS | Dual lens, He-Ne laser P>3.0 MW (λ= 632.8nm) | |
| Auxiliary green semiconductor laser (λ= 405 nm) P>2.0MW , | ||
| Laser Safety | Class 1 | |
| Wet dispersion | Ultrasonic | Frequency:40KHz Power:60W, Time: ≥1S |
| Stir | Revolutions Speed: 0-3000RPM (Adjustable) | |
| Circulate | Rated Flow:30L/min Rated Power:70W | |
| Sample tank | Volume:1000mL | |
| Micro- | Volume: 10mL ( Available) | |
| Sample cuvette | ||
| Dry dispersion | Dry-turbulence dispersion patent, normal shock wave shear technique | |
| Feeding Speed | Adjustable (Variable speed knob) | |
| Operation Mode | Full automatic / manual control, freely choose | |
| Dispersion medium | Compressed Air, pressure: 0 to 6 bar | |
| Optical bench alignment system | Full automatic, precision is up to 0.2um | |
| Measurment Time | Wet: <2 Min Dry : <1min Typical measuring time<10S | |
| Outer dimension(L*W*H) | 104×44×54cm | |
| Net Weight | 70Kg | |
1. Wider measuring range
2. Rotation speed is selected as full-range stepless speed change,
3. The RTD temperature probe can monitor and measure the temperature of the sample in real time
4. A number of mathematical statistical analysis tasks such as fully automated data collection, data storage and historical data comparison can be carried out through the optional software
![]() | Optional matching Thermostatic baths
A-LC1008 Refrigerant, environmentally friendly R134a A-RC0508 Packing weight: 20.5kg |
| Model | VSC-S1 | VSC-S2 | VSC-S3 | VSC-SA |
| Measuring Range(mPa·s) | 20~600,000 | 12~6,000,000 | 160~80,000,000 | 50~10,000,000 |
| Rotating Speed(RPM) | 1~60(Stepless Gear) | 0.1~99.9(Stepless Gear) | 0.1~99.9(Stepless Gear) | 0.1~200(Stepless Gear) |
| Number of Spindles | Spindles (Code L1, L2, L3, L4) are equipped with the product | Spindles (Code 21, 27, 28, 29) are equipped with the product | ||
| Accuracy | ±1% full scale range in use | |||
| Repeatability | ±0.5% full scale range in use | |||
| Readability | 1. when viscosity is lower than 10.0 cp: 0.01 | |||
| 2. when viscosity is lower than 10000 cp: 0.1 | ||||
| 3. when viscosity is equal or higher than 10000 cp: 1 | ||||
| Power | Power adapter (input: 100-240V,50/60Hz) | |||
| LCD screen display | The LCD screen can display the viscosity, speed, torque spindle, temperature and the maximum viscosity can be measured in the current spindle speed value. | |||
| Pakage size(mm) | 400*350*360 | 420*360*530 | ||
| Weight(kg) | 8kg | 9.3kg | ||
Apparatus to be equipped
| digital viscosity meter | 1 pce | ascending and falling rack | 1 set |
| standard spindle | 1 set | power adapter | 1 pce |
| protective frame of spindle | 1 pce | spanner | 1 pce |
| Seat and leveling feet | 1 set | RS232 standard output interface | 1 pce |
| RTD temperature probe | 1 pce |
Options
It is widely used in research and development, process optimization and quality control in various fields such as plastics, rubber, coatings, pharmaceuticals, catalysts, inorganic materials, metal materials and composite materials.
Features
| Model | TGA-1550 |
| Temperature Range | RT.~1550℃ |
| Temperature Resolution | 0.01℃ |
| Temperature Fluctuation | ±0.1℃ |
| Heating Rate | 0.1~100℃/min |
| Temperature Control Mode | PID control, heating, constant temperature and cooling |
| Program Control | Program setting multi-stage temperature rise and constant temperature, and five sections can be set at the same time |
| Balance Measuring Range | 0.01mg ~ 3g, which can be extended to 50g |
| Precision | 0.01mg |
| Constant Temperature Time | Program control, 0-300min, which can be extended to 72h |
| Resolution | 0.1μg |
| Display | LCD display |
| Atmosphere Device | Built-in gas flow meter, including two-way gas switching and flow control |
| Software | Intelligent software can automatically record TG curve for data processing, TG / DTG, mass, percentage coordinates can be arbitrarily switched;Software with automatic adjustment function, according to the map display, automatic extension, scaling |
| Gas Path | Can be set with multi-stage automatic switching without manual adjustment. |
| Data Interface | Standard USB interface, special software (software upgrade for free from time to time) |
| Electricity | AC220/110V, 50/60Hz |
| Curve Scanning | Heating scanning and cooling scanning |
| Test Map | Five test maps can be opened at the same time for comparative analysis |
| Cooling Time | ≤15min,1000℃~RT.;Air cooled cooling device is selected to reduce temperature quickly and improve test efficiency |
| Crucible Type | Ceramic crucible, aluminum crucible |
| External Dimension | 531*463.5*416mm |
| N.W./G.W. | 26kg/39kg |
| Shipping Dimension | 730*600*480mm |
| Parameters/Model | MTP-2C | MTP-2A | MTP-1C | MTP-1B | MTP-2 |
| Measuring range | RT~360℃ | RT~300℃ | RT~400℃ | RT~320℃ | RT~300℃ |
| Measuring mode | Auto | ||||
| Measuring methods | 8 | ||||
| Resolution | 0.1℃ | ||||
| Linear heating-up rate | 0.1℃/min~20℃/min | ||||
| Accuracy | ≤200℃:±0.4℃;>200℃:±0.7℃ | ||||
| Repeatability | 0.3℃(heating rate:1.0℃/min) | ||||
| Linear heating rate error | ±10% | ||||
| Number of capillary | 3 | 1 | |||
| Capillary dimensions | Outer diameter:φ1.4mm Inner diameter:φ1.0mm Length:90mm | ||||
| Height of sample | 3mm | ||||
| Data storage | 1000 set | / | 1000 set | / | / |
| Display | 7 inch touch LCD | ||||
| Printer(Thermal) | Standard accessory | / | Optional accessory | Optional accessory | / |
| Interface | RS232,USB | ||||
| Power supply | 100~240VAC,50/60Hz,100W | ||||
| Package Dimension | 580mm×445mm×320mm | 500mm×445mm×330mm | |||
| Weight(Gross) | 13kg | 11kg | |||
| Parameters/Model | MTP-3A |
| Measuring range | Room temperature -360℃ |
| Measuring mode | Auto/Visual |
| Resolution | 0.1℃ |
| Linear heating-up rate | 0.1℃/min-10℃/min |
| Accuracy | ≤200℃:±0.5℃;>200℃:±0.8℃ |
| Repeatability | 0.3℃(heating rate:1.0℃/min) |
| Linear heating rate error | ±10% |
| Number of capillary | 3 |
| Capillary dimensions | Outer diameter: φ1.4mm Inner diameter:φ1.0mm Length:90mm |
| Height of sample | 3mm |
| Display | 5.6 inch color touch screen |
| Calibration method | Multi-point calibration |
| Data storage | 100 sets |
| Interface | U disk,USB,RS232 |
| Power supply | 220V±22V,50Hz±1 Hz,180w |
| Package Dimension (W*D*H)(mm) | 510*450*390mm |
| Weight G.W.(kg) | 8.8kg |
Your dedicated partner in providing high-quality laboratory and research equipment. With years of industry experience, we specialize in supplying cutting-edge laboratory instruments, research equipment, and essential lab tools to support scientific discovery, educational advancement, and innovation across various industries.
© 2025 | REIDIUS TECHNOLOGIES | All Rights reserved.